PCI Nanocret® FC
Fiber-reinforced concrete smoothing compound
for walls and soffits
Areas of application
- For indoor and outdoor use.
- For wall and overhead application.
- For repair of honeycombs, filling of voids.
- For resurfacing brickwork and render.
- As fairing coat on concrete, fair-faced concrete and aerated concrete.
- For leveling irregular wall surfaces prior to laying tiles and flagstones.
- As leveling compound in swimming pools.
- Fairing coat after concrete repair with PCI Peciment 50 at vertical fair-faced concrete surfaces not exposed to foot traffic in civil engineering and bridge construction to ZTV-ING for PCC II application: surfaces not exposed to vehicular traffic and subject to dynamical loads (e.g. bridge soffits).
- As fairing coat for OS 4 or OS 5a coatings in accordance with DAfStb.
- For layer thickness from 1 to 10 mm.
Fairing coat of PCI Peciment II system tested to DAfStb guideline "Protection and repair of concrete elements" (German committee for reinforced concrete).
With official test certificate.
Listed as repair mortar to ÖBV (Austrian quality label).
Product features
- Low shrinkage during the curing phase.
- Waterproof, resistant to weather conditions and frost, multi-purpose use indoors and out.
- Creamy consistency after adding water, easy to apply.
- Fast setting, however processing time approx. 45 minutes.
- Fine-grained surface, therefore no need to be painted over.
- Mechanical and manual application.
- Tested to DAfStb guideline "Protection and repair of concrete elements".
- Suitable for exposure classes X0 and XF1-4 as described in EN 206
- Certified to EN 1504-3 R2.
Colors:
grey
Forms of delivery:
25-kg-bag/ 5-kg-bag
Consumption calculator
Your Result
Quantity Required * approx
kg
equivalent *
25-kg-bag
pieces
5-kg-bag
pieces
*
This consumption calculation included in the program contains approximate values based on experiences which might considerably vary upwards and also downwards depending on the structure of substrate, type of tiles, different profiles on the reverse sides, type of tiling tools, work method a.o. Calculations are therefore not allowed to be based on these values. In case of larger projects we recommend to assess the consumption by making a trial surface. Applications in the combined method (buttering-floating) increase the consumption by approx. 20 to 25%. In case of powder products the data relate to the consumption of dry powder for easier calculation of the material requirement.
Building pros also use:
Matching product systems
More product systemsReferences
YOUR DIRECT CONTACT
Downloads
Technical data sheet
Declaration of performance EN 1504-3 (R2)
Sustainability data sheet
Classification report EN 13501-1 (A2-s1,d0)
Combined with product:
PCI Nanocret® FC
Licensing GEV EMICODE (EC1 PLUS)
Combined with product:
PCI Nanocret® FC